Gas Analyzers

You are here:
Categories

Showing 1–6 of 15 results

Add to Wishlist
Add to Wishlist

ZAF

  • Best suited for H2, He, and Ar measurement
  • Ideal for H2, Ar, and He measurement
  • Easy-to-see LCD
  • RS-232C communication (option) Compact, panel mount design
  • Automatic calibration (option)
  • Interference compensation (option)
  • Interference compensation (option)
  • High/low limit, high-high limit, or low-low limit
  • Range switching (option)
  • by key on the front panel or by an external contact input.
Add to Wishlist
Add to Wishlist
Add to Wishlist
Add to Wishlist

ZAFE

  • Ideal for H2, Ar, and He measurement Ideal for H2, Ar, and He measurement Easy-to-see LCD RS-232C communication (option) Compact, panel mount design Automatic calibration (option) Interference compensation (option) Concentration alarm (option) High/low limit, high-high limit, or low-low limit Range switching (option) by key on the front panel or by an external contact input. NEPSI (Exd IIC T6Gb) certified
Add to Wishlist
Add to Wishlist
Add to Wishlist
Add to Wishlist

ZAJ

  • Fast response , Communication function, Ideal for measuring oxygen in combustible gas Fast response within 2 seconds Tolerant to interference
  • Non-contact detector with long-term superior stability
  • Highly sensitive mass flow sensor enables low concentration measurement Long-life detector with no moving parts
  • Interference compensation (option)
Add to Wishlist
Add to Wishlist
Add to Wishlist
Add to Wishlist

ZKG

  • No need for reference gas Ideal for measuring oxygen in flammable gas Dumbbell type paramagnetic system requires no reference gas Suited for oxygen in flammable gas Interference effect is negligible Japanese type approval
Add to Wishlist
Add to Wishlist
Add to Wishlist
Add to Wishlist

ZKJ

  • Double-beam NDIR sensor , Continuous measurement of up to 5 components
  • Simultaneous and continuous measurement of up to 5 components among: NO, SO2, CO2, CO, CH4, N2O, and O2
  • Ideal for flue gas monitoring in incinerators and industrial furnaces The mass flow type twin detector — hardly affected by interference gas A variety of functions: auto calibration, O2-corrected output, averaging, alarm, etc
  • Easy-to-see LCD
  • You can check the concentration changes of all components at a glance 19-inch rack mount Maximum range ratio 1 : 25
  • A user can set or change a range within the limit Zero drift for 200 ppm range: ≤ ±1% FS per week
Add to Wishlist
Add to Wishlist
Add to Wishlist
Add to Wishlist

ZKM1, ZKM2, ZFK8

  • Insertion type, No need for gas sampling device, Measures O2 in incombustible gas In-situ oxygen analysis requires no gas sampling device
  • Ideal for combustion control in industrial boilers and furnaces FEATURES
  • Easily replaceable zirconia element Fast response (4 to 7 seconds) IP66 or IP67 enclosure
  • Operation available without opening the cover (ZKM1 only) Safe design
  • High safety level
  • The converter cuts off the power supply for the detector when detecting a burnout of thermocouple
  • The converter also cuts off the power supply at emergency, in response to an external contact input.
  • The key lock function prevents operational errors.