Fuji Electric

You are here:
Categories

Showing 1–6 of 10 results

Add to Wishlist
Add to Wishlist

UPS6000D 1

  • Configuration of up to 8 parallel systems possible,Online UPS system ,Single-phase, 20 to 75 kVA
  • Network system support We have developed a Web/SNMP card for UPS systems that is compatible with JEMA-MIB. Monitoring of UPS status information is possible over an in-house LAN using browser software, and can also be used for remote maintenance. (The Web/SNMP card is optional.)
  • Harmonic current suppression The input current is controlled to be a sinusoidal wave and the harmonic current is suppressed. For this reason, there is no influence by harmonics on in-house power generators of the input system and phase advance capacitors.
  • High power factor Controlling the input current to be in phase with the voltage nearly eliminates the reactive power and makes the input power factor to be approximately 1, and this enables the input capacity to be reduced.
Add to Wishlist
Add to Wishlist
Add to Wishlist
Add to Wishlist

UPS6000D 3

  • High-level performance by means of high-speed switching, On-line type UPS,Three-phase, three-wire, 400 to 1,000 kVA
  • High-level performance by means of high-speed switching The UPS 6000D-3 series makes use of new fifth-generation IGBTs that have lower loss and improved high-frequency switching characteristics compared with conventional IGBTs *1, which enables higher reliability and higher performance. *1 Insulated Gate Bipolar Transistor
  • High reliability thanks to independent control and monitoring units The control unit and monitoring unit are independent, and the monitoring unit uses redundant software and hardware for high reliability.
  • IGBT power modules for high reliability High reliability is achieved by the use of an integrated configuration of IGBTs, fuses, and drive circuits, and large current panels for the wiring. In addition, the modules use a plug-in tray structure and maintenance is possible from the front side.
  • Full digitalization by means of the latest control processors Full digitalization using high-performance processors has greatly reduced the number of parts and achieved high reliability.
Add to Wishlist
Add to Wishlist
Add to Wishlist
Add to Wishlist

UPS6000DX T3

  • Supporting the high-level requirements of ICT equipment On-line type UPS
  • Three-phase, three-wire, 100 to 300 Kva Support for high power factor loads (kVA = kW) With the widespread use of power factor correction (PFC) circuits, power can be supplied effectively to load equipment with high power factors (1.0).
  • High output power density (kW/m2) The industry's highest output power [kW] per installation area has been achieved by increasing the output power [kW] in the same installation space required by conventional units. (300 kVA unit)
  • Redundant cooling fans By means of an efficient arrangement of multiple small cooling fans, power supplied by the UPS can be continued even if one cooling fan stops. This function improves the availability of the system. (When operating in the recommended operating environment.)
  • Support for various types of systems This UPS is adaptable to the configuration of high-reliability systems (parallel redundant operation mode, common stand-by operation, etc.), and by applying our own fully independent parallel redundant operation method, which does not have a common control section, parallel redundant operation systems can be constructed. Up to 8 units can be operated in parallel, and large-scale system configurations are supported. In addition, this UPS can be applied to various types of systems such as collective busbar, multiple busbar, common battery and others.
Add to Wishlist
Add to Wishlist
Add to Wishlist
Add to Wishlist

UPS6100D 3

  • Wide capacity series from 10 kVA to 50 kVA,Online UPS system,Three-phase, 10 to 50 kVA
  • High performance This online UPS system continually supplies power without interruption at a constant voltage and constant frequency.
  • Wide capacity series With six models available from 10 kVA to 50 kVA, users can select the best model for their load system.
  • Parallel operation possible Parallel operation of UPS systems can be done easily, such as for capacity expansion to match future load increases and for redundant operation to improve reliability.
  • High functionality with high reliability Uses a high power factor converter with IGBTs to control the AC input power factor to almost 1.0, and harmonic current suppression control at the same time Power walk-in function reduces shock to input power Battery service life monitoring functions UPS remote monitoring functions by means of monitoring software Network compatible functions when using network agent card
Add to Wishlist
Add to Wishlist
Add to Wishlist
Add to Wishlist

UPS7000HX T3

  • About a 40% reduction in device mass compared to previous models,On-line type UPS,Three-phase, three-wire, 500 kVA
  • The world's highest level of device efficiency at 97% Reducing power losses in UPS equipment by 40% contributes to improved PUE * in data centers.
  • Support for various high-reliability systems We provide systems like common stand-by and parallel redundant systems that can continuously provide a supply of power 24 hours a day, 365 days a year.
  • Compact, lightweight design Reduced footprint of facility equipment enables space to be secured for server equipment.
  • New power conversion New three-level conversion technology using new device RB-IGBTs reduces switching losses and cuts harmonic components by half, enabling a high-efficiency, compact and lightweight configuration.
Add to Wishlist
Add to Wishlist
Add to Wishlist
Add to Wishlist

UPS7000HX T4

  • High-capacity UPS features high reliability and high functionality,On-line type UPS,Three-phase, four-wire, 400 to 500 kVA
  • High efficiency of 96.5 % achieved with a three-phase, four-wire constant inverter power supply system-T-NPC* 3-level (new 3-level) conversion technology Application of Fuji-made RB-IGBT elements Circuit rationalization, such as transformerless isolation, by means of DC voltage control Significant reduction in running cost *AT-NPC : Advanced T-type Neutral Point Clamped
  • High reliability achieved through systemization and our pro ven track record Synchronized switchover system with bypass Parallel redundant system Standby redundant system Soft start to suppress inrush current Power walk-in function Battery service life assessment Simple Network Management Protocol (SNMP) (It can respond by using an option)
  • Compact and lightweight design We reduced the footprint of the facility equipment while maintaining the space for servers.